[1]陈丽斐,杨文荣.低压变配电系统谐波监测与治理技术[J].河北工业大学学报,2016,(04):6-11.[doi:10.14081/j.cnki.hgdxb.2016.04.002]
 Chen Lifei,Yang Wenrong.Low-voltage power distribution system harmonic monitoring and control technology[J].Journal of Hebei University of Technology,2016,(04):6-11.[doi:10.14081/j.cnki.hgdxb.2016.04.002]
点击复制

低压变配电系统谐波监测与治理技术()
分享到:

《河北工业大学学报》[ISSN:1007-2373/CN:13-1208/T]

卷:
期数:
2016年04期
页码:
6-11
栏目:
出版日期:
2016-07-31

文章信息/Info

Title:
Low-voltage power distribution system harmonic monitoring and control technology
作者:
陈丽斐杨文荣
(河北工业大学 电气工程学院,天津 300131)
Author(s):
Chen Lifei Yang Wenrong
关键词:
低压供电系统电能质量谐波无源滤波器有源滤波器
Keywords:
voltage power supply system power quality harmonic passive power filter active power filter
分类号:
TN713
DOI:
10.14081/j.cnki.hgdxb.2016.04.002
文献标志码:
A
摘要:
随着社会的发展,各种新型的用电设备得到广泛的使用,由于设备运行所要求的高安全性和精确性,对电能的使用和需求产生了更高的要求,但非线性负荷大量使用却带来了严重的电力污染。通过对某公司变配电室的低压变配电系统进行谐波实际监测,对监测结果做出了较为详细的描述,详细分析了谐波对电气设备危害。然后探讨了谐波治理的一般方法,针对该低压配电系统提出了一种有效的谐波治理措施并检测出了试运行后的结果,最后通过对比谐波治理前后数据,分析该技术方案优势。
Abstract:
With the development of society,a variety of new electrical equipment is widely used,due to the high security and accuracy of the equipment required to run,a higher demand has generated about using and demanding for electricity,but the extensive use of non-linear loads has brought serious power pollution.Through harmonic actually monitor a power distribution system of a company’s low-voltage power distribution room,made a more detailed description of monitoring results and gived a detailed analysis of harmonics on electrical equipment hazards.Then discussed the general method of harmonic control,proposed an effective harmonic control measures against the low-voltage distribution system and detected the results of the test after then,compared the harmonic data before and after and analyzed the advantages of the technology program.

参考文献/References:

[1].杨洪耕, 惠锦, 侯鹏. 电力系统谐波和间谐波检测方法综述[J]. 电力系統及其自动化学报, 2010, 22(2):65-69.
[2].GB/T14549-1993,《电能质量公用电网谐波》[S].309-310.
[3].罗安.电网谐波治理和无功补偿技术及装备[M].北京:中国电力出版社.2006.39-40.
[4].王智忠,李颖峰. 中低压配电网无功补偿[J].电气时代,2010,05:62-63
[5].Li D, Chen Q, Jia Z, et al. A high-power active filtering system with fundamental magnetic flux compensation[J]. IEEE Transactions on Power Delivery, 2006, 21(2):823-830.
[6].George J.Wakileh.电力系统谐波-基本原理、分析方法和滤波器设计[M].北京:机械工业出版社.徐政译.2003.58-62.
[7].翁利民.电力电子技术与谐波抑制,无功补偿技术研究综述[J].电力电容器,2004,3:6-10

更新日期/Last Update: 2016-10-28